Reports been run in the Day: View Reports section on the tills flicker, and cannot be viewed.

Reports been run in the Day: View Reports section on the tills flicker, and cannot be viewed.

Set the  ‘NoFlicker’ policy where Crystal Reports are flickering on POS stations.

This can only be set up through the INI file by adding the policy to the Pixel32.ini file, directly under the desired Station.

E.g.

[Station3]

NoFlicker=2

Possible values for this policy are as follows:

0 - all disabled

1 - no flicker enabled

2 - composite windows enabled

3 - both no flicker and composite windows enabled

Default = 3.



    • Related Articles

    • Unable to run backups in PixelPos

      Unable to run backups in PixelPos Published The PixelPoint Database BackUp system may experience problems if you attempt to back up a database that was created on an operating system using different regional settings. For example, if a database is ...
    • Issue with tax and VAT discrepancies after tax change and Last Orders use

      When Last Trans on a Member Record is used to add a new order all the old prices and taxes are applied to the products - in Pixel V12 at least. Remove LastTrans, 2 & 3 fields Run the following query in FPB update dba.member set ...
    • Changing the Vat rate in PixelPos V12

      Setting or Changing Vat Rates in PixelPoint Setting up the Tax Rates VAT rates are set in Pixel Back Office, in System Setup in the Administrator menu.  Note: Access to this feature usually requires the highest security level so can only be done by ...